Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomech ; 45(9): 1724-7, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22542221

RESUMO

Given that automobile crashes are the largest single cause of death for pregnant females, scientists are developing advanced computer models of pregnant occupants. The purpose of this study is to quantify the dynamic material properties of the human uterus in order to increase the biofidelity of these models. A total of 19 dynamic tension tests were performed on pregnant human uterus tissues taken from six separate donors. The tissues were collected during full term Cesarean style deliveries and tested within 36 h of surgery. The tissues were processed into uniform coupon sections and tested at 1.5 strains/s using linear motors. Local stress and strain were determined from load data and optical markers using high speed video. The experiments resulted in a non-linear stress versus strain curves with an overall average peak failure true strain of 0.32±0.112 and a corresponding peak failure true stress of 656.3±483.9 kPa. These are the first data available for the dynamic response of pregnant human uterus tissues, and it is anticipated they will increase the accuracy of future pregnant female computational models.


Assuntos
Gravidez/fisiologia , Útero/fisiologia , Feminino , Humanos , Estresse Mecânico , Resistência à Tração
2.
Curr Eye Res ; 37(4): 279-85, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22440159

RESUMO

PURPOSE: Interactive water displays are becoming increasingly popular and can result in direct eye contact. Therefore, the purpose of this study is to investigate eye injury risk from high speed water stream impacts and to provide biomechanically based design parameters for water toys and water park fountains. METHODS: An experimental matrix of 38 tests was developed to impact eight porcine eyes with water streams using a customized pressure system. Two stream diameters (3.2 mm and 6.4 mm) were tested at water velocities between 3.0 m/s and 8.5 m/s. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve and used to determine the injury risk for hyphema, lens dislocation, retinal damage, and globe rupture for each impact. RESULTS: Experimental water stream impacts created a range of intraocular pressures between 3156 mmHg and 7006 mmHg (61 psi to 135 psi). Injury risk varied between 4.4%-27.8% for hyphema, 0.0%-3.0% for lens dislocation, and 0.1%-3.3% for retinal damage. All tests resulted in 0.0% injury risk for globe rupture. The two water stream diameters did not result in significantly different water stream velocities (P = 0.32); however, the variation in water stream diameter did result in significantly different intraocular pressures (P = 0.03) with higher pressures for the 6.4 mm stream. CONCLUSIONS: This is the first study to experimentally measure intraocular pressure from high speed water stream impacts and quantify the corresponding eye injury risk. It is recommended that toy water guns and water park fountains use an upper threshold of 8.5 m/s for water stream velocities to minimize the risk of serious acute eye damage from impacts.


Assuntos
Traumatismos Oculares/fisiopatologia , Pressão Intraocular , Jogos e Brinquedos/lesões , Água , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Desenho de Equipamento , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/prevenção & controle , Pressão/efeitos adversos , Fatores de Risco , Suínos , Índices de Gravidade do Trauma
3.
Curr Eye Res ; 37(1): 43-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22029489

RESUMO

PURPOSE: To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts. METHODS: A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35 mm diameter metal ball, a 9.25 mm diameter aluminum rod, and an 11.16 mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns. RESULTS: A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture. CONCLUSIONS: Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.


Assuntos
Traumatismos Oculares/fisiopatologia , Pressão Intraocular/fisiologia , Estimulação Física/efeitos adversos , Ferimentos não Penetrantes/fisiopatologia , Animais , Modelos Animais de Doenças , Traumatismos Oculares/etiologia , Estimulação Física/métodos , Fatores de Risco , Suínos , Ferimentos não Penetrantes/etiologia
4.
J Biomech Eng ; 133(6): 064501, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21744930

RESUMO

This study reports the results of 38 infraorbital maxilla impacts performed on male cadavers. Impacts were performed using an unpadded, cylindrical impactor (3.2 kg) at velocities between 1 and 5 m/s. The peak force and acoustic emission data were used to develop a statistical relationship of fracture risk as a function of impact force. Acoustic emission sensors were used to provide a noncensored measure of the maxilla tolerance and were essential due to the increase in impactor force after fracture onset. Parametric and nonparametric techniques were used to estimate the risk of fracture tolerance. The nonparametric technique produced an estimated 50% risk of fracture between 970 and 1223 N. The results obtained from the parametric and nonparametric techniques were in good agreement. Peak force values achieved in this study were similar to those of previous work and were unaffected by impactor velocity. The results of this study suggest that an impact to the infraorbital maxilla is a load-limited event due to compromise of structural integrity.


Assuntos
Maxila/lesões , Acústica , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Engenharia Biomédica , Cadáver , Humanos , Técnicas In Vitro , Masculino , Maxila/fisiopatologia , Fraturas Maxilares/etiologia , Fraturas Maxilares/fisiopatologia , Pessoa de Meia-Idade , Modelos Biológicos , Fatores de Risco , Estatísticas não Paramétricas , Ferimentos não Penetrantes/fisiopatologia
5.
J Biomech Eng ; 133(2): 021004, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21280876

RESUMO

The current understanding of the tolerance of the frontal bone to blunt impact is limited. Previous studies have utilized vastly different methods, which limits the use of statistical analyses to determine the tolerance of the frontal bone. The purpose of this study is to determine the tolerance of the frontal bone to blunt impact. Acoustic emission sensors were used to provide a noncensored measure of the frontal bone tolerance and were essential due to the increase in impactor force after fracture onset. In this study, risk functions for fracture were developed using parametric and nonparametric techniques. The results of the statistical analyses suggest that a 50% risk of frontal bone fracture occurs at a force between 1885 N and 2405 N. Subjects that were found to have a frontal sinus present within the impacted region had a significantly higher risk of sustaining a fracture. There was no association between subject age and fracture force. The results of the current study suggest that utilizing peak force as an estimate of fracture tolerance will overestimate the force necessary to create a frontal bone fracture.


Assuntos
Osso Frontal/fisiologia , Estresse Mecânico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antropometria , Fenômenos Biomecânicos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Osso Frontal/diagnóstico por imagem , Osso Frontal/lesões , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Tomografia Computadorizada por Raios X
6.
Ann Adv Automot Med ; 54: 3-14, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21050587

RESUMO

The nasal bone is among the most frequently broken facial bone due to all types of trauma and is the most frequently fractured facial bone due to motor vehicle collisions. This study reports the results of anterior-posterior impacts performed on male cadavers using a free-falling impactor with a flat impacting surface. The force at fracture onset was determined using an acoustic emission sensor. These non-censored data were utilized in parametric and non-parametric techniques to determine a relationship between applied force and fracture risk. Based on these analyses a 50% risk of fracture corresponded to an applied force of approximately 450 to 850 N. There was no correlation between fracture force and anthropometric measures of the nasal bone. Interestingly, age had a statistically significant relationship with the risk of nasal bone fracture. This study demonstrates the need for a non-censored measure of fracture occurrence when evaluating structures that can continue to support load after fracture onset.


Assuntos
Osso Nasal , Fraturas Cranianas , Acidentes de Trânsito , Cadáver , Ossos Faciais , Fraturas Ósseas , Humanos
7.
Clin J Sport Med ; 20(6): 422-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21079437

RESUMO

OBJECTIVE: The goals of this study were to measure the ability of catcher's masks to attenuate head accelerations on impact with a baseball and to compare these head accelerations to established injury thresholds for mild traumatic brain injury. DESIGN: Testing involved using a pneumatic cannon to shoot baseballs at an instrumented Hybrid III headform (a 50th percentile male head and neck) with and without a catcher's mask on the head. The ball speed was controlled from approximately 26.8 to 35.8 m/s (60-80 mph), and the regulation National Collegiate Athletic Association baseballs were used. SETTING: Research laboratory. PATIENTS: None. INDEPENDENT VARIABLES: Catcher's masks and impact velocity. MAIN OUTCOME MEASURES: The linear and angular head accelerations of the Hybrid III headform. RESULTS: Peak linear resultant acceleration was 140 to 180 g without a mask and 16 to 30 g with a mask over the range of ball's speed investigated. Peak angular resultant acceleration was 19 500 to 25 700 rad/s without a mask and 2250 to 3230 rad/s with a mask. The Head Injury Criterion was 93 to 181 without a mask and 3 to 13 with a mask, and the Severity Index was 110 to 210 without a mask and 3 to 15 with a mask. CONCLUSIONS: Catcher's masks reduced head acceleration metrics by approximately 85%. Head acceleration metrics with a catcher's mask were significantly lower than contemporary injury thresholds, yet reports in the mass media clearly indicate that baseball impacts to the mask still occasionally result in mild traumatic brain injuries. Further research is needed to address this apparent contradiction.


Assuntos
Aceleração , Beisebol/lesões , Lesões Encefálicas/prevenção & controle , Dispositivos de Proteção da Cabeça , Máscaras , Equipamentos Esportivos , Adulto , Humanos , Masculino , Modelos Biológicos , Índice de Gravidade de Doença
8.
J Biomech Eng ; 131(9): 091008, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19725697

RESUMO

Automobile crashes are the largest cause of injury death for pregnant females and the leading cause of traumatic fetal injury mortality in the United States. Computational models, useful tools to evaluate the risk of fetal loss in motor vehicle crashes, are based on a limited number of quasistatic material tests of the placenta. This study presents a total of 64 uniaxial tensile tests on coupon specimens from six human placentas at three strain rates. Material properties of the placental tissue were evaluated at strain rates of 0.07/s, 0.70/s, and 7.00/s. The test data have average failure strains of 0.34, 0.36, and 0.37, respectively. Failure stresses of 10.8 kPa, 11.4 kPa, and 18.6 kPa correspond to an increase in strain rate from 0.07/s to 7.0/s. The results indicate rate dependence only when comparing the highest strain rate of 7.0/s to either of the lower rates. There is no significant rate dependence between 0.07/s and 0.70/s. When compared with previous testing of placental tissue, the current study addresses the material response to more strain rates as well as provides a much larger set of available data. In summary, tensile material properties for the placenta have been determined for use in computational modeling of pregnant occupant kinematics in events ranging from low impact activities to severe impacts such as in motor vehicle crashes.


Assuntos
Modelos Biológicos , Placenta/fisiologia , Gravidez/fisiologia , Simulação por Computador , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Estresse Mecânico , Resistência à Tração/fisiologia , Viscosidade
9.
J Biomech ; 42(10): 1493-1497, 2009 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-19428016

RESUMO

As a result of trauma, approximately 30,000 people become blind in one eye every year in the United States. A common injury prediction tool is computational modeling, which requires accurate material properties to produce reliable results. Therefore, the purpose of this study was to determine the dynamic material properties of the human sclera. A high-rate pressurization system was used to create dynamic pressure to the point of rupture in 12 human eyes. Measurements were obtained for the internal pressure, the diameter of the globe, the thickness of the sclera, and the changing coordinates of the optical markers using high-rate video. A relationship between true stress and true strain was determined for the sclera tissue in two directions. It was found that the average maximum true stress was 13.89+/-4.81 MPa for both the equatorial and meridional directions, the average maximum true strain along the equator was 0.041+/-0.014, and the average maximum true strain along the meridian was 0.058+/-0.018. Results show a significant difference in the maximum strain in the equatorial and meridional directions (p=0.02). In comparing these data with previous studies, it is concluded that the human sclera is both anisotropic and viscoelastic. The dynamic material properties presented in this study can be used for advanced models of the human eye to help prevent eye injuries in the future.


Assuntos
Esclera/lesões , Esclera/fisiologia , Anisotropia , Fenômenos Biomecânicos , Elasticidade , Traumatismos Oculares/etiologia , Traumatismos Oculares/fisiopatologia , Humanos , Técnicas In Vitro , Pressão Intraocular , Modelos Biológicos , Ruptura , Esclera/fisiopatologia , Estresse Mecânico , Gravação em Vídeo , Viscosidade
10.
Arch Ophthalmol ; 127(4): 520-3, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19365034

RESUMO

OBJECTIVE: To determine the dynamic rupture pressure of the human eye by using an in vitro high-rate pressurization system to investigate blunt-impact eye injuries. METHODS: Internal pressure was dynamically induced in the eye by means of a drop-tower pressurization system. The internal eye pressure was measured with a small pressure sensor inserted into the eye through the optic nerve. A total of 20 human eye tests were performed to determine rupture pressure and characterize rupture patterns. RESULTS: The high-rate pressurization resulted in a mean (SD) rupture pressure of 0.97 (0.29) MPa (7275.60 [2175.18] mm Hg). A total of 16 eyes ruptured in the equatorial direction, whereas 4 ruptured in the meridional direction. There was no significant difference in the rupture pressure between the equatorial and meridional directions (P= .16). CONCLUSION: As the loading rate increases, the rupture pressure of the human eye increases. CLINICAL RELEVANCE: Eye injuries are expensive to treat, given that the estimated annual cost associated with adult vision problems in the United States is $51.4 billion. Determining globe rupture properties will establish injury criteria for the human eye to prevent these common yet devastating injuries.


Assuntos
Tecido Elástico/lesões , Traumatismos Oculares/fisiopatologia , Pressão , Esclera/lesões , Ferimentos não Penetrantes/fisiopatologia , Fenômenos Biomecânicos , Elasticidade , Humanos , Modelos Biológicos , Ruptura , Transdutores de Pressão , Gravação em Vídeo
11.
Biomed Sci Instrum ; 45: 107-12, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19369748

RESUMO

Half of eye injuries in the United States are caused by a blunt impact and more specifically, eye injuries effecting children often result from projectile shooting toys. The purpose of this study is to evaluate the risk of eye injuries of currently available projectile shooting toys. In order to assess the risk of each toy, a Facial and Ocular Countermeasure Safety (FOCUS) headform was used to measure the force applied to the eye during each hit for a total of 18 tests. The selected toys included a dart gun, a foam launcher, and a ball launcher. The force ranged from 4-93 N and was analyzed using the injury risk function for globe rupture for the FOCUS headform. Projectile characteristics were also examined using normalized energy to determine risk of corneal abrasion, hyphema, lens dislocation, retinal damage and globe rupture. It was found that the three toys tested produced peak loads corresponding with risk of globe rupture between 0% and 17.3%. The normalized energy results show no risk of hyphema, lens dislocation, retinal damage or globe rupture and a maximum risk of corneal abrasion of 5.9%. This study concludes that although there are many eye injuries caused by projectiles, the selected toys show a very low risk of eye injury.

12.
Biomed Sci Instrum ; 45: 389-94, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19369794

RESUMO

With the increasing use of computational models there is a growing need to establish and analyze the material properties of biological tissues. The purpose of this study is to analyze and compare the various methods used for reporting stress and strain for biological materials. For this study, three biological materials (bone, sclera, and placenta) were used to compare the effects of reporting stress and strain relationships using various formulations. For each material the engineering, 2nd Piola Kirchhoff and true stresses were calculated along with the engineering, Green-Lagrangian, and true strains. The energetic equivalents were then plotted to investigate the various formulations. As expected, it was found that for strain values less than 5% the various formulations were not significantly different but as the strain increased (30%) the non-linear terms began to increase the difference between the formulations to a maximum of 36%. Also, to represent a material correctly, the energy conjugates must be used together. Measuring the true stress and true strain relationship is advantageous given that most computational models use this formulation.

13.
J Biomech ; 41(16): 3436-40, 2008 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-18996533

RESUMO

Automobile crashes are the largest cause of injury death for pregnant females and the leading cause of traumatic fetal injury mortality in the United States. Computational models, useful tools to evaluate the risk of fetal loss in motor vehicle crashes, are based on a limited number of quasi-static material tests of the placenta. This study presents a total of 20 dynamic uniaxial tensile tests on the maternal side of the placenta and 10 dynamic uniaxial tensile tests on the chorion layer of the placenta. These tests were completed from 6 human placentas to determine material properties at a strain rate of 7.0 strains/s. The results show that the average peak strain at failure for both the maternal portion and the chorion layer of the placenta are similar with a value of 0.56 and 0.61, respectively. However, the average failure stress for the chorion layer, 167.8 kPa, is much higher than the average failure stress for the placenta with the chorionic plate removed, 18.6 kPa. This is due to differences in the structure and function of these layers in the placenta. In summary, dynamic loading data for the placenta have been determined for use in computational modeling of pregnant occupant kinematics in motor vehicle crashes. Moreover the computational model should utilize the material properties for the placenta without the chorion layer.


Assuntos
Modelos Biológicos , Placenta/fisiologia , Simulação por Computador , Módulo de Elasticidade/fisiologia , Feminino , Humanos , Estimulação Física/métodos , Estresse Mecânico , Resistência à Tração/fisiologia
14.
Biomed Sci Instrum ; 44: 117-22, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19141903

RESUMO

Over 1.9 million people suffer from eye injuries in the United States, occurring from automobile accidents, sports related impacts, and military combat. The purpose of the current study is to analyze the rupture pressure of human eyes using a high rate pressurization system. Internal pressure was dynamically induced into the eye with a drop tower pressurization system. The rupture pressure was measured with a small pressure sensor inserted into the optic nerve. A total of 10 human eye dynamic pressure tests were performed to determine rupture pressure and to compare the results with previous data. It was found that the average high rate rupture pressure of human eyes is 0.89+/- 0.25 MPa. In comparing these data with previous studies, it is concluded that as the loading rate increases the rupture pressure also increases.

15.
Biomed Sci Instrum ; 44: 147-52, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19141907

RESUMO

This study describes a method for utilizing Acoustic Emission (AE) in facial fracture detection and demonstrates the association between fracture and acoustic emission magnitude. AE sensors were mounted to the frontal bone and mandible of cadaver skulls (n=14) exposed to impacts to the frontal bone, nasal bone, maxilla and mandible. The presence of AE during fracture and non-fracture tests necessitated the development of a threshold to distinguish AE associated with fracture. Based on the obtained data, a threshold of 9 volts was established. The association between above-threshold AE and fracture was demonstrated by performing low-severity impacts on pre-fractured frontal bones. These tests demonstrated that above threshold AE is produced as a result of high-severity impacts, resulting in fracture as well as low-severity impacts on prefracture bone. The results of these tests indicate that above threshold AE was associated with the fracture process and not a function of the force applied to the facial bones.

16.
Biomed Sci Instrum ; 44: 177-82, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19141912

RESUMO

As a result of trauma, approximately 30,000 people become blind in one eye every year in the United States. A common injury prediction tool used for eye injuries is computational modeling, which requires accurate material properties to produce reliable results. The purpose of this study is to determine the dynamic material properties of the human sclera. A high rate pressurization system was used to create a dynamic pressure event to the point of rupture in 5 human eyes. Measurements were obtained for the internal pressure, the diameter of the globe, and the changing coordinates of the optical markers. A relationship between true stress and Green-Lagrangian strain was determined for each test specimen in the x and y direction to show directional effects. It was found that the average maximum true stress was 10.45 +/- 2.28 MPa, the average maximum Green-Lagrangian strain in the x-direction was 0.041 +/- 0.012, and the average maximum Green-Lagrangian strain in the y-direction was 0.073 +/- 0.015. In comparing these data with previous studies, it is concluded that the human eye is both anisotropic and viscoelastic. This study presents dynamic material properties that can be used for establishing injury criteria to help prevent eye injuries in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...